Spec Care Dentist ; 44(1): 124-129, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37013961

RESUMO

OBJECTIVE: To present clinical strategies for prosthetic rehabilitation with complete dentures (CDs) of a Parkinson's disease patient. CASE REPORT: An 82-year-old patient sought the Department of Dentistry at UFRN, reporting retention dissatisfaction and hamper to the mandibular CD adaptation. Patient-reported a dry mouth sensation, and exhibited disordered mandibular movements, tremors, and resorbed mandibular ridge. Aiming retention and stability, double molding with zinc enolic oxide impression paste, neutral zone technique, and non-anatomic teeth were proposed as clinical strategies. At delivery, identification and relief in the supercompression areas were performed to facilitate the acceptance and use of the new dentures. CONCLUSION: The strategies promoted patient satisfaction regarding retention, stability, and comfort. This treatment may be considered for the rehabilitation of Parkinson's disease patients, favoring the adaptation process.


Assuntos
Doença de Parkinson , Humanos , Idoso de 80 Anos ou mais , Doença de Parkinson/complicações , Planejamento de Dentadura/métodos , Retenção de Dentadura/métodos , Prótese Total , Satisfação do Paciente
2.
J Mech Behav Biomed Mater ; 150: 106269, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38043259

RESUMO

BACKGROUND: The stud-shaped attachment systems (AS) with different shape designs (ball, cylindrical, conical) and materials (metallic, plastic, or a combination of both) are commonly used to provide better retention and stability in implant-retained mandibular overdentures (IRMO). PURPOSE: The purpose of the present study was to evaluate and compare the retention loss and the wear (patterns, location, material loss) of three resilient unsplinted AS: a well-established ball attachment system (BAS) and two more recent cylindrical attachment systems (CAS), Locator R-Tx® and Novaloc®. MATERIALS AND METHODS: The implants, their corresponding abutments, the color-coded or position-coded retention devices (RD), the matrix metal housing were incorporated within CAD/CAM resin blocks and cyclically loaded with 19.6 N along the implant axis in a chewing machine to simulate 10,000 insertion-removal cycles (IRC). At cycle 10, 100, 1,000, 5,000, and 10,000, the retention force was measured using a universal testing machine. The wear was qualitatively examined using a binocular magnifier for both systems, and quantitatively assessed from micro-computed tomography acquisitions for CAS. Material loss exceeding 50 µm was considered significant. RESULTS: The three AS showed different retentive behavior along time. All the Locator R-Tx® RD lost more than 50 % of their retention after 10,000 IRC. The retention of the Ball System slightly varied over time, the final retention loss in Bmed and Bmax groups being lower than 25 % of the initial retention. Wear was located at the tip of their gold RD and at the equator area of their ball abutment. For Locator R-Tx®, the more retentive the plastic RD, the greater its wear and retention loss. Only Novaloc® maintained a stable retention with even a slight tendency to increase and showed a negligible wear. Implant abutments of the CAS showed no significant wear. CONCLUSION: After 10,000 IRC, corresponding to approximately 5-years clinical use, almost all RD provided retention force over 5 N, which could be sufficient to maintain satisfaction in most of the patients. The retention loss observed most prominently for the Locator R-Tx®, then for the Ball System, seemed to correlate with the wear observed on their RD. The practitioner may expect less RD maintenance with the Novaloc® stable retention overtime.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Humanos , Retenção de Dentadura/métodos , Microtomografia por Raio-X , Mandíbula , Análise do Estresse Dentário
3.
Clin Implant Dent Relat Res ; 26(1): 103-112, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37926953

RESUMO

OBJECTIVES: This study aimed to evaluate the clinical outcomes and patient satisfaction of 4-implant-assisted maxillary overdentures using two different designs. MATERIALS AND METHODS: Thirty edentulous participants received four implants in the maxillary ridge. The patients were randomly divided into two equal groups: (1) the control (CG, Vertical) group (n = 15); participants received four vertical implants with straight locator attachments to retain maxillary overdentures, and (2) the study (SG, Angled) group (n = 15); participants received four angled implants with angled locator attachments to retain maxillary overdentures. Peri-implant tissue health [Plaque (PL) and gingival (GI) indices, pocket depth (PD), implant stability (ISQ) and crestal bone loss (CBL)] were evaluated after denture insertion (T0), 6 (T6), and 12 (T12) months after insertion. Patient satisfaction was evaluated using a visual analog scale (VAS) after 12 months. RESULTS: The survival rates were 96.7% and 95% for the control and study groups respectively. PL, GI, and PD increased significantly in both groups with the passage of time. No significant difference in PL, GI, PD, and ISQ was noted between groups at all observation times. CG showed higher CBL than SG at T12. For the VAS results, there was no significant difference between groups. SG recorded significantly higher satisfaction regarding comfort with maxillary and mandibular dentures, retention of mandibular dentures, oral hygiene, the ability to chew hard food, and occlusion than CG. CONCLUSION: Within the limitations of this study, angled implants with angled locator attachments may be recommended to retain maxillary overdentures opposing intact dentition or fixed restoration as it was associated with improvements of several parameters of peri-implant tissue health and patient satisfaction compared to vertical implants with straight locator attachments.


Assuntos
Implantes Dentários , Placa Dentária , Arcada Edêntula , Humanos , Revestimento de Dentadura , Retenção de Dentadura/métodos , Satisfação do Paciente , Mandíbula , Prótese Dentária Fixada por Implante
4.
J Prosthodont ; 33(2): 164-170, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36779671

RESUMO

PURPOSE: To investigate the retentive behavior of the Locator legacy and Novaloc attachment systems with different retention inserts both within and across systems under cyclic load. MATERIALS AND METHODS: Three retention inserts of each system (green, yellow, and white for Novaloc; green, orange, and red inserts for extended range for legacy Locator) were tested on abutments of both systems with a sample number of 10 per force and 10,000 cycles of insertion and removal. The loading was applied in the axial direction of the abutments, which were placed in artificial saliva. The retention force was measured in each cycle. The results were compared with the manufacturer's specifications and evaluated for a simulated period of use of 10 years. Characteristic time constants were determined, and subsequently, the two systems were compared regarding their wear behavior. RESULTS: The manufacturer's specifications could only be confirmed for the green Novaloc retention insert on a Novaloc abutment (t-test: p = 0.50); for all other inserts, the baseline exceeded the manufacturer's specifications by 30%-75% (Novaloc; t-test: p < 0.001) and 75%-550% (Locator; t-test: p < 0.001). After 10,000 cycles performed, the manufacturer's specifications were confirmed on a Novaloc abutment for the white Novaloc retention insert (t-test: p = 0.86) and on a Locator abutment for the green Novaloc retention insert (t-test: p = 0.32). Both systems lost retention force during the experiment. Overall, Novaloc inserts on both abutments showed less wear (decrease to 56%-85% of initial force) and a slower decrease in retention force compared to Locator inserts (decrease to 6%-31% of initial force). CONCLUSIONS: In both systems, wear leads to a varying loss of retention; therefore, regular checks with possible replacement of the inserts are necessary in clinical use. Novaloc attachments seem to be more resistant to the loss of retention than Locator attachments. A cross-combination may be clinically useful in some cases.


Assuntos
Implantes Dentários , Retenção de Dentadura , Retenção de Dentadura/métodos , Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Saliva Artificial
5.
Eur J Med Res ; 28(1): 520, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37968756

RESUMO

PURPOSE: This study aims to evaluate the digitally designed ball attachment housing in its initial retentive force and after 2 years of simulated clinical use and to compare it with the regular nylon ball attachment housing. MATERIALS AND METHODS: Twenty implants with their corresponding ball abutments (diameter 4.5 × 4.0 mm) were inserted in resin blocks. They were divided into two groups. In Group I, ten ball abutments each received their corresponding conventional attachment with nylon rings. In Group II, ten ball abutments received the novel CAD-CAM polyetheretherketone ball attachment housing. A universal testing machine was used to measure the retention force. The achieved maximum values of retention force were recorded at the beginning of the study (initial retention) and after 2 years of artificial ageing (2000 cycles of insertion and removal). Results were statistically analyzed using an independent sample T test. RESULTS: The PEEK attachment housing showed high retention forces (25.12 ± 0.99 N) compared to the conventional attachment with a nylon ring (15.76 ± 0.93 N) in the initial dislodgement test. There was a statistically significant difference in mean retention at the initial retention test and after 2 years of stimulated usage between the two studied groups, p = 0.000. CONCLUSIONS: Within the limitations of this study, the novel CAD-CAM-PEEK attachment showed high retention characteristics compared to the conventional attachment with nylon rings, initially and after simulated long-term use.


Assuntos
Habitação , Nylons , Humanos , Retenção de Dentadura/métodos , Revestimento de Dentadura , Teste de Materiais , Polietilenoglicóis , Cetonas , Desenho Assistido por Computador
6.
Dent Med Probl ; 60(1): 167-176, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37023344

RESUMO

The ball attachments and their O-rings used for the retention and stabilization of overdentures showed a decrease in retention as the number of cycles increased. This fact resulted in a decrease in the retention of the prosthesis. The purpose of this study was to evaluate the fatigue resistance of ball attachments through a systematic review. An electronic search was performed using the Cochrane Library, LILACS, PubMed, ScienceDirect, and Web of Science databases. The search was conducted based on the PICOS framework. The inclusion criteria involved in the search comprised research articles written in English and published between the years 2000 and 2020. In the final selection, 18 articles were included in the review. Most of these studies performed the fatigue retention tests using parallel implants without angles. However, some studies used different angles to analyze the fatigue retention values. With the passage of time, the wear results in deformation and, as a consequence, a decrease in the retention of most attachments, leading to treatment failure. The main factor to be considered is the loss of retention of these components and their low durability. The loss of retention is due to large extent to the materials used to manufacture the attachments and O-rings, the size and angulation of the implants, and the length of the prosthesis. Future research is needed to further elucidate the reasons for the failure of the attachments.


Assuntos
Implantes Dentários , Humanos , Prótese Dentária Fixada por Implante/métodos , Retenção de Dentadura/métodos , Revestimento de Dentadura
7.
J Oral Implantol ; 49(3): 330-339, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-36796061

RESUMO

When extended distally due to higher loading in the posterior region, implant-supported bar-retained overdentures with cantilever bar extension exhibit greater bending moments on the implants closest to the cantilever bar and increased stresses in the overdenture components. In this study, a new abutment-bar structure connection was introduced to minimize undesired bending moments and reduce the resulting stresses by increasing the rotational mobility of the bar structure on the abutments. Copings of the bar structure were modified to have 2 spherical surfaces, sharing the same center, located at the centroid of the top surface of the coping screw head. The new connection design was applied to a 4 implant-supported mandibular overdenture to create a modified overdenture. Both the classical and modified models had bar structures with cantilever extensions in the first and second molar areas and were analyzed for deformation and stress distribution using finite element analysis, which was also conducted for both the overdenture models without cantilever bar extensions. Real-scale prototypes of both models with cantilever extensions were manufactured, assembled on implants embedded in polyurethane blocks, and subjected to fatigue testing. Both models' implants were subjected to pullout testing. The new connection design increased the rotational mobility of the bar structure, minimized the bending moment effects, and reduced the stress levels in the peri-implant bone and overdenture components, whether cantilevered or not. Our results verify the effects of rotational mobility of the bar structure on the abutments and validate the importance of the abutment-bar connection geometry as a design parameter.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Prótese Dentária Fixada por Implante/métodos , Análise do Estresse Dentário/métodos , Mandíbula , Retenção de Dentadura/métodos
8.
Compend Contin Educ Dent ; 44(1): e5-e9, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36649497

RESUMO

Rehabilitation of edentulous patients with implant-supported overdentures has gained prominence over the use of conventional dentures because of the improved quality of life it provides patients. Various attachment systems are available that facilitate the insertion and removal of prostheses, and among them, the Locator attachment system has become popular due to its self-aligning property, simplicity of use, and minimal space requirement of male inserts within the denture. However, the loss of retention of nylon inserts over time requires their removal from the metal housing and subsequent replacement. This article describes an easy alternative technique for replacing the nylon inserts in the denture cap using a simple dental explorer and mirror head.


Assuntos
Nylons , Qualidade de Vida , Humanos , Masculino , Retenção de Dentadura/métodos , Prótese Dentária Fixada por Implante/métodos , Mandíbula , Materiais Dentários , Revestimento de Dentadura
9.
J Prosthodont ; 32(2): 162-169, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35344237

RESUMO

PURPOSE: Primary retention and gradual loss of retention of different attachment systems are important key factors in proper attachment selection; however, studies on attachment retention show a wide range of retention values concerning the same attachment system. This in vitro study uses a novel approach that utilizes a digitally designed and 3D-printed reinforced overdenture, which has a digitally determined geometric center, in order to standardize results for future research and clinical work. This study aims to evaluate initial retention along with the gradual loss of retention at different time intervals between three types of stud attachments, retaining a digitally designed, reinforced mandibular overdenture after 5475 cycles simulating 5 years of attachment usage. MATERIALS AND METHODS: An epoxy model of an ACP Class I (American College of Prosthodontists) edentulous mandible was constructed. A fully computer-designed surgical guide was employed after virtual denture design to place two implants according to prosthetically driven implant placement protocol. A metal meshwork with tissue stops was designed digitally to reinforce the denture and to carry the geometric center. The meshwork was incorporated into the denture-intaglio surface, which was planned for attachment pickup. Forty-eight digitally designed and metal-reinforced 3D-printed dentures were divided into four groups (12 dentures for each group). Loss of retention was measured to compare two novel Locator attachments (12 pairs of Locator R-TX, 12 pairs of Locator F-TX medium and low retention, with 12 pairs of ball and socket). Each group was subjected to an insertion and removal fatigue test resembling 5 years of patient usage. Retention values were recorded using a universal testing machine. RESULTS: Locator F-TX medium and low retention showed loss of retention by 91.93% and 92.91%, after fatigue testing equivalent to 2 and 3 years of use, respectively. Ball and socket and Locator R-TX showed loss of retention by 19.87% and 26.31%, respectively, after fatigue testing equivalent to 5 years of use. CONCLUSIONS: Locator R-TX attachment systems showed promising retention for implant overdentures compared to ball and socket attachments. The proposed digital technique of denture reinforcement is capable of standardizing results for research and clinical work.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Humanos , Retenção de Dentadura/métodos , Prótese Dentária Fixada por Implante/métodos , Análise do Estresse Dentário , Mandíbula
10.
Gerodontology ; 40(1): 135-141, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35416323

RESUMO

OBJECTIVES: This study aimed to compare differences between complete denture conditions self-rated by older adult wearers and clinically exanimated by a professional based on standardised aesthetics and functional criteria. MATERIALS AND METHODS: Complete denture clinical examination was based on the functional (stability, retention, occlusion and articulation, vertical dimension of occlusion) and aesthetics criteria. Data on self-rated complete denture conditions were measured using the Patient's Denture Assessment (PDA) questionnaire based on standardised aesthetic and functional criteria (n = 122). Prevalence rates of clinical and self-rated complete denture condition, sensitivity, specificity, positive and negative predictive values, and absolute and relative bias were calculated. RESULTS: The highest sensitivity (66.7% [95% CI 55.3-76.7]) was obtained for aesthetic criterion, whereas occlusion revealed the lowest sensitivity (14.9% [95% CI 6.2-28.3]). Stability had the highest specificity (91.3% [95% CI 72.0-98.9]) and aesthetics the lowest (21.4% [95% CI 8.3-41.0]). Stability also yielded the highest positive predictive value (83.3% [95% CI 51.6-97.9]), and vertical dimension of occlusion the lowest (26.3% [95% CI 9.1-51.2]). The vertical dimension of occlusion yielded the highest negative predictive value (71.2% [95% CI 58.7-81.7]). Self-rated data underestimated the complete denture condition in 6.5% compared with clinical examinations when the aesthetic criterion was excluded from the analysis and 7.6% when added. CONCLUSIONS: Older adult wearers better identified the condition of their complete denture when the aesthetic criterion was excluded from examination. In contrast, considering functional criteria (retention, stability, occlusion and vertical dimension of occlusion), self-rated complete denture conditions underestimated clinical examination. CLINICAL RELEVANCE: Using standardised aesthetic criteria in epidemiological studies for assessing complete denture conditions self-rated by wearers could avoid underestimating or overestimating the information regarding the use or need for dental prostheses.


Assuntos
Retenção de Dentadura , Prótese Total , Humanos , Idoso , Retenção de Dentadura/métodos , Oclusão Dentária
11.
Int J Prosthodont ; 36(5): 612-619, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33662066

RESUMO

PURPOSE: To investigate the physical and mechanical behaviors of polyether ether ketone (PEEK) before and after thermocycling, as well as its potential use as a more durable prosthetic component for implant-supported and -retained removable dental prostheses (I-RDPs). MATERIALS AND METHODS: Roughness and surface hardness were evaluated in specimens obtained using the subtractive method (n = 20) with a diameter of 9 mm and a thickness of 2 mm, and retention force was measured using attachments with a diameter of 4 mm and a height of 3 mm. For fatigue resistance testing, a polyurethane matrix with two ball abutment implants (MDL, Intra-Lock International) was used to simulate the mandibular alveolar ridge. A total of 40 attachments (n = 20 pairs) were placed in acrylic resin blocks using an analog technique for the direct clinical pickup of overdenture female attachments, then submitted to 2,900 insertion/removal cycles to simulate 24 months of overdenture use. Physical analyses were performed by Fourier-transform infrared spectroscopy (FTIR), x-ray diffraction (XRD), and differential scanning calorimetry (DSC) before and after thermocycling (5°C to 55°C for 10,000 cycles). After normal distribution was verified by Shapiro-Wilk test, one-way ANOVA was applied to analyze the surface roughness and hardness, and two-way ANOVA with Bonferroni adjustment was used to assess the retention force (α = .05). RESULTS: Thermocycling did not change the PEEK surface roughness or hardness (P > .05). As for the retention force, the highest average was observed after the thermocycling test (P = .006). CONCLUSION: Based on the FTIR, XRD, and DSC results, PEEK crystallinity decreased after thermocycling, and the physical and mechanical behaviors of this polymer were compatible with the proposed application, suggesting that PEEK is a component of greater durability for I-RDPs. Int J Prosthodont 2023;36:612-619.


Assuntos
Implantes Dentários , Dente , Feminino , Humanos , Resinas Acrílicas/química , Revestimento de Dentadura , Polietilenoglicóis , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Retenção de Dentadura/métodos
12.
Int J Prosthodont ; 36(5): 554-562, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36484663

RESUMO

PURPOSE: To assess oral health-related quality of life (OHRQoL) and patient satisfaction with a three-implant-retained mandibular overdenture. MATERIALS AND METHODS: In this randomized crossover clinical trial, 20 edentulous patients received a new set of conventional complete dentures (CDs; baseline). Subsequently, three implants were placed in the anterior mandible: two were placed in the canine regions bilaterally and one in the midline. After successful osseointegration, CDs were attached to the implants using resilient attachments. The overdenture was retained either by three implants (test group) or two implants (control group). The sequence of treatment was randomized such that each patient experienced both treatment options for 6 months each. OHRQoL was assessed at baseline and after 6 months of function for each treatment option using the Oral Health Impact Profile (OHIP-14) and visual analog scale (VAS) scores. Statistical analyses were performed using Friedman and Wilcoxon signed rank tests. RESULTS: CD resulted in significantly higher OHIP-14 and VAS scores (25.25 + 6.42, 8.55 + 1.73) compared to both the control group (11.15 + 5.39, 4 + 2; P < .001) and the test group (6.25 + 4.02, 2.06 + 1.48; P < .001). Similarly, significantly higher mean OHIP-14 and VAS scores were noted for the control group compared to the test group (P < .001). CONCLUSIONS: Overdentures retained by three implants resulted in better OHRQoL scores and higher patient satisfaction compared to overdentures retained by two implants and CDs. Int J Prosthodont 2023;36:554-56.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Satisfação do Paciente , Revestimento de Dentadura , Qualidade de Vida , Arcada Edêntula/cirurgia , Prótese Dentária Fixada por Implante , Retenção de Dentadura/métodos , Mandíbula/cirurgia
13.
J Contemp Dent Pract ; 24(11): 834-839, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238269

RESUMO

AIM: This study was conducted to evaluate peri-implant bone height changes and posterior ridge resorption by using two-implant retained polyetheretherketone (PEEK) overdentures with locator attachments following expansion of mandibular knife edge ridges by ridge splitting. MATERIALS AND METHODS: Eighteen patients were selected for ridge splitting followed by expansion, implant placement, and bone graft application. Six months later, the fabrication of PEEK overdentures retained by locator attachments was accomplished. Friedman test, Wilcoxon signed-rank test, and Spearman correlation were used to evaluate the changes over time. RESULTS: Peri-implant bone height loss increased significantly with the advance of time between 6 and 12 months following denture insertion. Posterior area index changes were significant over time when measured at the time of denture insertion and twelve months following denture insertion. CONCLUSION: The effect of using PEEK as overdenture base material retained with two locator attachments allowed sharing the load between the peri-implant bone anteriorly and residual ridge posteriorly in cases with ridge splitting technique. CLINICAL SIGNIFICANCE: Using PEEK as an overdenture base material is a successful means of bone preservation. How to cite this article: Helmy MA, El-Shaheed NH, El Waseef FA, et al. Effect of Ridge Splitting of Mandibular Knife Edge Ridges with Two-implant Retained Overdenture with Locator Attachments on Peri-implant Bone Level and Posterior Ridge Resorption: A One-year Preliminary Study. J Contemp Dent Pract 2023;24(11):834-839.


Assuntos
Benzofenonas , Implantes Dentários , Revestimento de Dentadura , Polímeros , Humanos , Prótese Dentária Fixada por Implante , Mandíbula/cirurgia , Retenção de Dentadura/métodos
14.
Int J Oral Maxillofac Implants ; 37(5): 982-988, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36170313

RESUMO

PURPOSE: To evaluate strain around resilient stud and bar attachments for inclined implants supporting mandibular overdentures during loading and dislodging. MATERIALS AND METHODS: A mandibular edentulous model was printed using the laser sintering technique. Two vertical implants and two 30-degree distally inclined implants were placed in canine and premolar areas, respectively. Overdentures were attached to the implants with either a resilient stud (Locator, group 1) or a bar/clip (group 2) attachment. Three strain gauges were mounted at the buccal, lingual, and proximal surfaces of each implant. Microstrains were registered during vertical loading and dislodging force applications and compared between attachments (resilient stud and bar) and implant positions (vertical and inclined). RESULTS: For canine implants, bar overdentures recorded significantly higher microstrains than Locator overdentures during vertical loading. For premolar (inclined) implants, Locator overdentures recorded significantly higher microstrains than bar overdentures during vertical dislodging. For both groups (during loading) and the bar overdenture group (during dislodging), canine (vertical) implants showed significantly higher microstrains than premolar (inclined) implants. CONCLUSION: Within the limitations of this in vitro study, canine (vertical) implants may be at risk of increased stresses during loading if bar attachments are used for vertical and inclined implants supporting mandibular overdentures, and premolar (inclined) implants may be at risk of increased stresses during dislodging if Locator attachments are used. For both attachments, canine implants showed significantly higher microstrains than premolar implants during loading and dislodging.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Prótese Dentária Fixada por Implante/métodos , Análise do Estresse Dentário , Retenção de Dentadura/métodos , Mandíbula/cirurgia
15.
J Prosthet Dent ; 128(3): 487.e1-487.e12, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35934574

RESUMO

STATEMENT OF PROBLEM: Daily denture brushing results in wear on implant-retained overdenture attachments. However, studies on the remaining denture attachment retention after brushing are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the retentive force of the retentive inserts in 3 denture attachments after brushing with different media. MATERIAL AND METHODS: Three retentive insert types in 3 denture attachments (LOCATOR, LOCATOR R-Tx, and Novaloc) were tested. Three abutments and 20 metal housings of each denture attachment were separately embedded into individual acrylic resin blocks, and 20 retentive inserts of each retentive type in each denture attachment were placed in the metal housing. The blocks embedded with a metal housing of each denture attachment were divided into 2 brushing media groups (n=10), mounted on a brushing machine, and brushed with deionized water (DI) or toothpaste slurry (TP). After 0, 10 000, and 20 000 brushing cycles, the block specimens were mounted on a universal testing machine, and the retentive force was evaluated by pulling the blocks apart until complete separation. The maximum retentive force was measured 5 times and averaged. The evaluated retentive insert was removed and replaced with a new retentive insert. The specimen blocks were subjected to another brushing test with the same protocol. Representative specimens of each group were examined with scanning electron microscopy. The retentive force of each retentive insert type in each denture attachment was analyzed by 2-way repeated measures ANOVA, followed by the Bonferroni test (α=.05). RESULTS: The retentive force of each LOCATOR and LOCATOR R-Tx retentive insert demonstrated significant differences in the interaction between brushing media and brushing cycles (P<.05). Between baseline and 20 000 brushing cycles with DI, the retentive force of the LOCATOR and LOCATOR R-Tx retentive inserts decreased significantly (P<.05). Between baseline and 20 000 brushing cycles with TP, the retentive force of the LOCATOR retentive inserts increased significantly (P<.05), while the retentive force of the LOCATOR R-Tx retentive inserts was statistically similar (P>.05). The retentive force of the Novaloc retentive inserts demonstrated significant differences only for brushing cycles (P<.05). The Novaloc retentive inserts decreased in average retentive force over time. CONCLUSIONS: After brushing with deionized water, the retentive forces of the LOCATOR, LOCATOR R-Tx, and Novaloc retentive inserts decreased, while, after brushing with toothpaste, the retentive force of the retentive inserts increased in the LOCATOR group, was unchanged in the LOCATOR R-Tx group, and decreased in the Novaloc group.


Assuntos
Prótese Dentária Fixada por Implante , Retenção de Dentadura , Resinas Acrílicas , Análise do Estresse Dentário , Retenção de Dentadura/métodos , Revestimento de Dentadura , Cremes Dentais , Água
16.
Molecules ; 27(12)2022 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-35745048

RESUMO

This study aimed to examine the retentive characteristics of each retentive element material and the effects from thermocycling using the two implant-retained mandibular overdenture model. Two stud abutments and three retentive element materials; nylon, polyetheretherketone (PEEK) and polyvinylsiloxane (PVS) were used in this study. Four tested groups, with a total of 40 overdentures, were fabricated, including a Locator® abutment with nylon retention insert (NY), Novaloc® abutment with PEEK retention insert (PK), Locator® abutment with PVS retention insert (RL), and Novaloc® abutment with PVS retention insert (RN). The retentive force (N) was measured before thermocycling, and at 2500, 5000, and 10,000 cycles after thermocycling. Significant changes in the percentage of retention loss were found in the NY and PK groups (p < 0.05) at 6 and 12 months for the RL group (p < 0.05) after artificial aging. The RN group exhibited a constant retentive force (p > 0.05). The tendency of the percentage of retention loss significantly increased for PEEK, nylon, and PVS silicone over time. The results of the present study implied that retentive element materials tend to lose their retentive capability as a result of thermal undulation and water dispersion. Nylon and PEEK, comprising strong polar groups in polymer chains, showed a higher rate of retention loss than polyvinylsiloxane.


Assuntos
Retenção de Dentadura , Revestimento de Dentadura , Retenção de Dentadura/métodos , Cetonas , Mandíbula , Nylons , Polietilenoglicóis
17.
Int J Prosthodont ; 35(1): 27-36, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35230353

RESUMO

PURPOSE: To digitally evaluate the static and dynamic occlusion of patients treated with both removable conventional complete dentures (CCDs) and implant-retained removable overdentures (IODs) and to correlate two different methods of occlusal analysis. MATERIALS AND METHODS: Eleven totally edentulous patients were treated with bimaxillary CCDs. Later, mandibular CCDs were replaced by IODs retained by either two or four implants. The distribution of the occlusal contacts in static and dynamic occlusion was compared by means of the digital method (DM; T-Scan III) and the analog method (AM; articulating paper). Scores 0, 1, and 2 were assigned for inadequate, satisfactory, and adequate distribution of the occlusal contacts, respectively. The frequencies of scores were compared in relation to the types of denture by means of Fisher exact test (P < .05). The correlation between methods was assessed by means of the kappa agreement coefficient (κ) and the correlation coefficient phi (φ) (P < .05). RESULTS: Significant differences between CCDs and IODs were found in the right lateral mandibular movement (DM, P = .024; AM, P = .008), as well as in the left lateral mandibular movement (DM, P = .035). The methods of analysis of the occlusion showed a moderate agreement (κ = 0.604; P < .001) and a moderate correlation (φ = 0.605; P < .001). CONCLUSION: The digital and analog methods showed a significant agreement and moderate correlation, irrespective of the type of complete denture. The T-Scan III digital system seems to be a consistent and reproducible method to analyze occlusion.


Assuntos
Implantes Dentários , Retenção de Dentadura , Prótese Dentária Fixada por Implante/métodos , Retenção de Dentadura/métodos , Prótese Total , Prótese Total Inferior , Revestimento de Dentadura , Humanos , Mandíbula , Satisfação do Paciente , Estudos Prospectivos , Qualidade de Vida
18.
J Prosthodont ; 31(9): 771-777, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35061925

RESUMO

PURPOSE: To estimate the effects of the thermal cycling (TC) process on the metal surfaces of Locators, as well as retention loss, and the correlation between them. MATERIALS AND METHODS: Twenty-five new Locator R-Tx were included in the study. Four areas were marked on each Locators' patrix metal surface and scanned using a confocal scanner (µsurf explorer; NanoFocus). Three surface roughness parameters were measured in the scans: Sa (average distance of peaks from the central plain of the area), Vmp (volume of the peaks in the area), and Spc (mean curvature of the peaks describing the degree of their sharpness). Retention test was performed using Instron® 4500 compression tension tensile tester at a speed of 10 mm/min. The retention tests were done using a working model made of two acrylic blocks in which the Locator system parts were inserted. The surface parameters measurements and the retention tests were performed 2 times, once before and once after TC. The Locators were subjected to 15,000 TC cycles by investing them into 2 tubs with different water temperatures, 55°C and 5°C. During each 60-second cycle, the Locators were submerged in each tub for 20 seconds, with a 10 second transition time between the tubs. The post-TC retention and surface parameters measurements were compared with those prior to TC and the prior to TC measurements served as controls. Changes in parameters before and after TC were analyzed by a two-way ANOVA nested model with random intercept and slope by restricted maximum likelihood method. Correlation between retention and surface parameters was quantified and examined using Kendall's correlation test. The findings were considered statistically significant if p < 0.05. RESULTS: There was a significant decrease in retention of 16.6N at the second retention test (p < 0.001). A significant statistical decrease in surface parameters were measured after TC process, Sa and Vmp (18 ×10-3 µm, p = 0.041 and 0.94 ×10-3 1/µm, p = 0.001, respectively). A significant statistical increase in Spc of 6.4 ×10-3 µm3 /µm2 (p = 0.023) was noticed. The correlation between retention decreases and surface changes was not statistically significant. CONCLUSION: The TC process causes a substantial reduction in retention to the Locator system over time. In addition, TC causes significant but minor changes to the Locator surface area. Most of the changes are in the horizontal dimension.


Assuntos
Retenção de Dentadura , Revestimento de Dentadura , Retenção de Dentadura/métodos , Análise do Estresse Dentário , Fatores de Tempo , Água , Propriedades de Superfície , Teste de Materiais
19.
J Prosthet Dent ; 127(2): 319.e1-319.e8, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34857392

RESUMO

STATEMENT OF PROBLEM: Frequent maintenance because of the limited lifetime of overdenture attachments with O-rings has led to the development of materials that might improve their functionality and longevity. However, testing of newly developed attachment materials is lacking. PURPOSE: The purpose of this in vitro study was to evaluate a newly developed attachment made of polyetheretherketone (PEEK) for an implant-retained overdenture. MATERIAL AND METHODS: Specimens of PEEK, polyacetal, and Teflon O-ring materials were prepared for analysis of roughness, surface hardness, and compressive strength. For the fatigue resistance test, new specimens based on acrylic resin were subjected to 2880 insertion and removal cycles. Compression and roughness data were compared with the Kruskal-Wallis and Dunn post hoc test; hardness data with ANOVA and t test; and fatigue and stereomicroscopy with ANOVA with repeated measures, t test, and Bonferroni adjustment (α=.05). RESULTS: Polyacetal had the lowest surface roughness (P=.038). There was a significant difference in hardness among the materials (P<.05). PEEK presented the highest compressive strength among the materials (P<.001). For the fatigue resistance, only polyacetal showed a difference between the initial time-point (P<.05) and subsequent time-points. Polyacetal had a higher fatigue resistance than Teflon (P<.001) and PEEK (P<.05). Regarding the internal deformation of the attachments, a significant difference was observed among the materials (P<.05). CONCLUSIONS: PEEK showed promising results regarding the physicomechanical properties necessary for use as an overdenture attachment when compared with other evaluated materials. In addition, the PEEK attachment showed results comparable to those in the control group (O-rings) in terms of retention.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Benzofenonas , Prótese Dentária Fixada por Implante/métodos , Análise do Estresse Dentário , Retenção de Dentadura/métodos , Teste de Materiais , Polímeros
20.
J Oral Implantol ; 48(2): 105-109, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33690796

RESUMO

The O-rings in ball retained overdentures deteriorate with time and need replacement to restore the retentive quality. We evaluated retrospectively the mechanical properties of O-rings after 3 years in function in 1 and 2-piece implant-supported overdentures. The O-rings were retrieved from one-piece (Myriad snap, Equinox-Straumann, 3.3 × 13 mm) and 2-piece (Neo Biotech, 3.3 × 13 mm) implant-supported overdenture patients. A total of 16 pairs of matrices were tested for wear, type of damage, and elasticity using Pin on Disc method, USB Digital Camera in 30× zoom and Universal Tensile Machine, respectively. The statistical analysis for independent groups were done with the Mann-Whitney U test. Assessment of used O-rings showed 84% more wear in the 2-piece system with an abrasive type of damage while 46% wear in the 1-piece system with a compressive type of damage. The O-rings in 1-piece system showed increase in elongation and maximum displacement to 2% and 7%, respectively, whereas the 2-piece system showed decrease in elongation and maximum displacement by 13% and 6%, respectively. In 1-piece system, the loss of retention was more with slow wear rate, and in 2-piece system, the wear resistance of O-rings decreased due to increased stiffness. Further studies to evaluate the changes in O-ring with increased sample size and at interval 1 year will pave way for insight into the progressive changes in the mechanical properties of an O-ring.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Retenção de Dentadura/métodos , Humanos , Estudos Retrospectivos